2 Mechanical Installation
- 25 -
2 Mechanical Installation
2.1 Storage and Transportation Precautions
2.1.1 Storage
The AC drive must be stored in a clean and dry room, with temperatures between -20℃
and +60℃ and temperature variation smaller than 1° C/min. If the AC drive is stored
for a prolonged period once it has been unpacked, cover it or take other appropriate
measures to ensure that it does not become dirty and that it is protected against
environmental in󶍿uences.
For storage of the AC drive, pay attention to the following three aspects:
Pack the AC drive with the original packing box provided by Inovance.
Do not expose the AC drive to moisture, high temperature, or outdoor direct
sunlight for a long time.
The electrolytic capacitor will deteriorate after being stored for a long time.
Therefore, the AC drive must be switched on once for at least 5 hours every 6
months. The input voltage must be increased slowly to the rated value by using a
voltage regulator. Contact professionals for technical support if necessary.
2.1.2 Transportation
Structures T2 to T5 are small and light and can be handled manually.
However, structures T6 to T12 are heavy, requiring suitable hoisting gear operated
by trained personnel. The equipment must be carried on a wooden pallet when
transported with forklifts. The equipment must be carried on a wooden pallet
when transported with cranes.