- 116 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
FC-21 1st fault subcode 0 to 1231 0 MM.DD
ā
FC-22 1st fault month and day 0 to 23.59 0 HH.MM
ā
FC-23 1st fault hour and minute 0 to 9999 0 -
ā
FC-24 2nd fault code 0 to 65535 0 -
ā
FC-25 2nd fault subcode 0 to 1231 0 MM.DD
ā
FC-26 2nd fault month and day 0 to 23.59 0 HH.MM
ā
FC-27 2nd fault hour and minute 0 to 9999 0 -
ā
FC-28 3rd fault code 0 to 65535 0 -
ā
FC-29 3rd fault subcode 0 to 1231 0 MM.DD
ā
FC-30 3rd fault month and day 0 to 23.59 0 HH.MM
ā
FC-31 3rd fault hour and minute 0 to 9999 0 -
ā
FC-32 4th fault code 0 to 65535 0 -
ā
FC-33 4th fault subcode 0 to 1231 0 MM.DD
ā
FC-34 4th fault month and day 0 to 23.59 0 HH.MM
ā
... ...
FC-207 60th fault code 0 to 9999 0 -
ā
FC-208 60th fault subcode 0 to 65535 0 -
ā
FC-209 60th fault month and day 0 to 1231 0 MM.DD
ā
FC-210
60th fault hour and
minute
0 to 23.59 0 HH.MM
ā
Group Fd: Communication parameters
Fd-00 Baud rate
0: 9600
1: 38400
1 bps
ā
Fd-02 Local address 0 to 127 1 -
ā
Fd-03
Communication response
delay
0 to 20 0 ms
ā
Fd-04 Communication timeout 0 to 60.0 0.0 s
ā
Fd-05 Re-leveling stop delay 0.00 to 2.00 0.00 s
ā
Fd-05 is used to set the delay from the moment when the elevator receives the leveling signal to the moment
when it starts to decelerate to stop.
Fd-07 HCB:JP1 input
0: Reserved
1: Elevator lock signal
2: Fire emergency signal
3: Present īoor forbidden
4: VIP īoor signal
5: Security īoor signal
6 Door close button signal
7: Second īære emergency īoor
signal
1 -
ā
Fd-08 HCB:JP2 input 2 -