- 118 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
Fd-31
Extension board 1 Y1
output
0: No function
1: Door machine 1 open
2: Door machine 1 close
3: Door machine 2 open
4: Door machine 2 close
5: Brake and RUN contactors
healthy (contactors abnormal if
E37 and E36 are reported)
6: Fault state
7: Running monitor
8: PMSM self-lock
9: System healthy
10: Emergency buzzer control
11: Higher-voltage startup of brake
12: Elevator running in up direction
13: Lamp/Fan running
14: Medical sterilization #
15: Non-door zone stop #
16: Electric lock #
17: Non-service state
18: Emergency evacuation
completed
19: Fire emergency (return to īære
emergency īoor and īæreīæghter
running)
20: Emergency at power failure
21: Door lock active
22: Running at night
0 -
ā
Fd-32
Extension board 1 Y2
output
0 -
ā
Fd-33
Extension board 1 Y3
output
0 -
ā
Fd-34
Extension board 1 Y4
output
0 -
ā
Fd-35
Extension board 1 Y5
output
0 -
ā
Fd-36
Extension board 1 Y6
output
0 -
ā
Fd-37
Extension board 1 Y7
output
0 -
ā
Fd-38
Extension board 1 Y8
output
0 -
ā
Fd-39
Extension board 1 Y9
output
0 -
ā
Fd-40
Extension board 1 Y10
output
0 -
ā
Fd-41
Extension board 2 Y1
output
0 -
ā
Fd-42
Extension board 2 Y2
output
0 -
ā
Fd-43
Extension board 2 Y3
output
0 -
ā
Fd-44
Extension board 2 Y4
output
0 -
ā
Fd-45
Extension board 2 Y5
output
0 -
ā
Fd-46
Extension board 2 Y6
output
0 -
ā
Fd-47
Extension board 2 Y7
output
0 -
ā
Fd-48
Extension board 2 Y8
output
0 -
ā
Fd-49
Extension board 2 Y9
output
0 -
ā
Fd-50
Extension board 2 Y10
output
0 -
ā
Group FE: Elevator function parameters
FE-00 Collective selective mode
0: Full collective selective
1: Down collective selective
2: Up collective selective
0 -
ā