- 85 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
Floor height 11 to īoor height 37
F4-80
High byte of īoor height
38
0 to 65535 0 Pulses
ā
F4-81
Low byte of īoor height
38
0 to 65535 0 Pulses
ā
F4-82
High byte of īoor height
39
0 to 65535 0 Pulses
ā
F4-83
Low byte of īoor height
39
0 to 65535 0 Pulses
ā
Group F5: Terminal function parameters
F5-00
Attendant/Automatic
switchover time
3 to 200 3 s
ā
F5-01 X1 function selection
01/33: Up leveling signal NO/NC
03/35: Door zone signal NO/NC
02/34: Down leveling signal NO/
NC
04/36: Safety circuit feedback NO/
NC
05/37: Door lock circuit feedback
NO/NC
06/38: RUN contactor feedback
NO/NC
07/39: Brake contactor feedback
NO/NC
22/54: Shorting door lock circuit
contactor feedback NO/NC
08/40: Inspection signal NO/NC
09/41: Inspection up signal NO/NC
10/42: Inspection down signal NO/
NC
12/44: Up limit signal NO/NC
13/45: Down limit signal NO/NC
16/48: Up slow-down 1 signal NO/
NC
17/49: Down slow-down 1 signal
NO/NC
18/50: Up slow-down 2 signal NO/
NC
19/51: Down slow-down 2 signal
NO/NC
82/114: Door lock 2 shorting NO/
NC
86/118: Door lock bypass input
NO/NC
Value for NC setting of a signal
= Value for NO setting of this
parameter + 32
Others:
00: Invalid
... (To be continued)
33 -
ā
F5-02 X2 function selection 35 -
ā
F5-03 X3 function selection 34 -
ā
F5-04 X4 function selection 4 -
ā
F5-05 X5 function selection 5 -
ā
F5-06 X6 function selection 38 -
ā
F5-07 X7 function selection 39 -
ā
F5-08 X8 function selection 22 -
ā
F5-09 X9 function selection 40 -
ā
F5-10 X10 function selection 09 -
ā
F5-11 X11 function selection 10 -
ā
F5-12 X12 function selection 44 -
ā
F5-13 X13 function selection 45 -
ā
F5-14 X14 function selection 48 -
ā
F5-15 X15 function selection 49 -
ā
F5-16 X16 function selection 50 -
ā
F5-17 X17 function selection 51 -
ā