6 Parameter Description
-
232
-
Group FA: Keypad setting parameters
Function
Code
Name Setting Range Default Unit Property
FA-00 Keypad display selection 0 to 3 3 -
☆
The NICE3000
new
system has three LEDs on the MCB. You can change the
display content through the setting of this parameter.
The values are as follows:
■
■
■
■
Function
Code
Name Setting Range Default Unit Property
FA-01 Display in running state 1 to 65535 65535 -
☆
FA-01 is used to set the running parameters displayed on the operation panel when
the elevator is in the running state.
FA-01 includes 5 binary bits. A total of 5 parameters can be displayed during running.
You can press the Shift key to perform shift between displayed parameters. Every pa-
rameter is controlled by a binary bit. If a bit is set to 1, the parameter indicated by this
bit is displayed; if this bit is set to 0, the parameter is not displayed. You can modify
this parameter according to your operating habit.
The 5 binary bits correspond to the running parameters listed in the following table.
Binary Bit Parameter Name Default
Bit0
Maximum
running speed
1
Bit1 Bus voltage 1
Bit2 Output Voltage 1
Bit3 Output current 1
Bit4 Output frequency 1