5 System Commissioning
- 
142
 -
This chapter describes the basic commissioning guide of the NICE3000
new
. By follow-
ing the instruction, you can perform complete commissioning on the elevator system 
and implement all basic normal running functions of the elevator.
5.1 System Commissioning Guide
 
Start
 End
Leveling accuracy 
adjustment
Riding comfort 
adjustment
Motor auto-tuning
Running test at 
inspection speed
 Safety and circuit 
check
Power-on and 
controller state check
 Commissioning at 
inspection speed
 Commissioning at 
normal speed
 Riding comfort 
adjustment
Shaft auto-tuning
Car commissioning
HCB commissioning
new
5.2 Safety and Circuit Check
Pay attentions to the following precautions before performing commissioning:
 
◆
The input and output terminals of the NICE3000
new
 have default setting at delivery. You 
can change the setting based on your requirements. The examples in this manual are all 
based on the default setting of the terminals.
1  System Wiring Diagram
Refer to Figure 2-39.