6 Parameter Description
- 
246
 -
parameter is valid when the manual door function is used.
FB-17 is used to set the holding time before forced door close is implemented.
If the forced door close function is enabled, the system enters the forced door close 
state and sends a forced door close signal when there is no door close signal after the 
time set in this parameter is reached.
Function 
Code
Name Setting Range Default Unit Property
Fb-20 Manual door lock waiting time 0 to 60 0 s
☆
This parameter is used to set interval time to wait from door lock unlocking and 
locking to the next running startup in the case of manual door.
Function 
Code
Name Setting Range Default Unit Property
Fb-24 UCMP test program version 0 to 65535 1 - 
Fb-24 is the program version of the UCMP test program module.
Group FC: Protection function parameters
Function 
Code
Name Setting Range Default Unit Property
FC-00 F5-33 Program control selection 0 to 65535 0 -
★
These parameters are used to select program control functions. If a bit is set to 1, the 
function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
FC-00 Program control selection
Bit Function Description Default
Bit0
Detection of short 
circuit to ground at 
power-on
Whether the motor is short circuited to ground 
is detected at power-on. If the motor is short 
circuited to ground, the controller blocks the output 
immediately, and reports the fault.
1
Bit1 Reserved - 0
Bit2
Decelerating to 
stop at valid light 
curtain
During normal-speed running, the elevator 
decelerates to stop immediately after the light 
curtain acts, and then runs to the registered 
function is mainly used in the case of manual door.
0