- 101 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-42
Program control selection
3
Bit1: Cancelling door open/close
command at delay after door open/
close limit
Bit2: Not judging door lock state at
door close output
Bit3: Door close command output
during running
Bit4: Returning to base oor for
verication at rst-time power-on
Bit5: Clearing calls immediately at
elevator lock
Bit6: Electric lock NC output
Bit7: E50 fault detection
cancellation
Bit8: Cancellation of door open/
close limit fault detection
Bit9: Cancellation of scrolling fault
subcode display
Bit10: Door open energy-saving
Bit11: Independent switch for
getting away from parallel control
0 -