EasyManua.ls Logo

Inovance Monarch NICE300new Series - Braking Resistor Selection Guide

Inovance Monarch NICE300new Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 16 -
1 Product Information
1
Item Specication
Protection
functions
(Continued)
Leveling switch fault
protection
Protection at fault of leveling switch
EEPROM fault Self-check at power-on
Display
Keypad 3-digit LED display, providing certain commissioning functions
Operating panel
5-digit LED display, viewing and modifying most parameters and
monitoring system state
Mobile phone commissioning Viewing and changing system state
Environment
Ambient temperature
-10°C to 40°C (de-rated if the ambient temperature is above
40°C, maximum temperature: 50°C)
Humidity Maximum relative humidity 95%, non-condensing
Vibration < 5.9 m/s2 (0.6g)
Storage temperature -–20°C to 60°C (temperature during transportation)
Location Indoor (no corrosive gas or dust)
Pollution degree PD2
Power supply system TN/TT
Altitude Below 1000 m (de-rated 1% for each 100 m higher)
Structure
Ingress protection IP20
Cooling method Forced air cooling
Mounting method Cabinet installation
1.5 Selection of Braking Resistor
Table 1-3 Braking component selection
Controller Model
Power of
Applicable Motor
(kW)
Max.
Resistance
(Ω)
Min.
Resistance
(Ω)
Power of
Braking Resistor
(W)
Braking Unit
Single-phase 220 V, range:220 to 240 V
NICE-L-C-2002 1.1 145.0 125.0 300
Built-in
NICE-L-C-2003 1.5 105.0 90.0 450
220-NICE-L-C-4007 2.2 72.0 63.0 600
220-NICE-L-C-4011 3.7 43.0 37.0 1100
220-NICE-L-C-4015 4.0 40.0 35.0 1200
220-NICE-L-C-4018
5.5 29.0 25.0 1600
220-NICE-L-C-4018F
220-NICE-L-C-4022
11.0 18.0 16.0 3500
Built-in
220-NICE-L-C-4022F
220-NICE-L-C-4030
15.0 13.0 13.0 4500
220-NICE-L-C-4030F
Three-phase 220 V, range: 220 to 240 V
NICE-L-C-2002 2.2 72.0 65.0 600
Built-in
NICE-L-C-2003 3.7 54.0 50.0 1100
220-NICE-L-C-4007 4.0 40.0 35.0 1200