- 106 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-45
Emergency evacuation
function selection
Bit0 to Bit1: Direction determine
mode
(00: Automatically calculating
direction; 01: Load direction
determining; 10: Direction of
nearest landing oor)
Bit2: Stopping at evacuation
parking oor
Bit4: Compensation at startup
Bit8: Emergency running time
protection
Bit10: Emergency buzzer output
Bit12: Shorting stator braking
mode switched over to controller
drive
Bit13: Mode of shorting stator
braking mode switched over to
controller drive
Bit14: Emergency evacuation exit
mode
Bit15: Shorting stator braking
function
0 -