4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
Group Fb: Door function parameters
Fb-00
Number of door
machine(s)
1 to 2 1 -
Fb-01 CTB software 00 to 999 0 -
Fb-02
Door machine 1 service
oors 1 (oors 1–16)
0 to 65535 65535 -
Fb-03
Door machine 1 service
oors 2 (oors 17–32)
0 to 65535 65535 -
Fb-04
Door machine 2 service
oors 1 (oors 1 to 16)
0 to 65535 65535 -
Fb-05
Door machine 2 service
oors 2 (oors 17 to 32)
0 to 65535 65535 -
These parameters are used to set the service oors of door machine 1 and door machine 2.
The setting method is the same as that for F6-05.
Fb-06
Door open protection
time
5 to 99 10 s
Fb-07 Arrival gong output delay 0 to 1000 0 ms
Fb-08
Door close protection
time
5 to 99 15 s
Fb-09
Door open/close
protection times
0 to 20 0 -
Fb-10
Door state of standby
elevator
0: Closing the door as normal at
base oor
1: Waiting with door open at base
oor
2: Waiting with door open at each
oor
0 -
Fb-11
Door open holding time
for hall call
1 to 1000 5 s
Fb-12
Door open holding time
for car call
1 to 1000 3 s
Fb-13
Door open holding time
at base oor
1 to 1000 10 s
Fb-14 Door open delay 10 to 1000 30 s
Fb-15
Special door open
holding time
10 to 1000 30 s
Fb-16
Manual door open
holding time
1 to 60 5 s
Fb-17
Holding time for forced
door close
5 to 180 120 s
Fb-18
Door machine 1 service
oors 3 (oors 33–40)
0 to 65535 65535 -
Fb-19
Door machine 2 service
oors 3 (oors 33–40)
0 to 65535 65535 -
Fb-20
Door lock waiting time of
manual door
0 to 60 0 -
Fb-24
UCMP detection program
version
0 to 65535 1 -