- 139 -
5 Troubleshooting
5
Fault Code Name Possible Causes Solution Level
Err36
RUN contactor
feedback
abnormal
Subcode 101: The
feedback of the RUN
contactor is active,
but the contactor has
no output.
Check whether the feedback contact of the
contactor acts properly.
Check the signal feature (NO, NC) of the
feedback contact.
5A
Subcode 102: The
controller outputs
the RUN signal but
receives no RUN
feedback.
Subcode 104: When
both feedback signals
of the RUN contactor
are enabled,
their states are
inconsistent.
Subcode 105: The
RUN contactor is
active before re-
leveling begins.
Subcode 103:
The current of the
asynchronous motor
from acceleration
to constant-speed
running is too small (≤
0.1 A).
Check whether the output cables UVW of the
controller are connected properly.
Check whether the control circuit of the RUN
contactor coil is normal.