- 37 -
2 System Commissioning
2
Motor Auto-tuning Flowcharts
1. Synchronous motor auto-tuning
a. Synchronous motor with-load auto-tuning (motor connected with car)
Operation Para. No. Parameter Name Default Commissioning
Start
Enter inspection
state
Turn the Automatic/Inspection switch to the Inspection position.
X9 indicator is OFF, indicating that the elevator enters inspection state.
Select command
source
F0-01
Command source
selection
1 1
0: Operation panel control
1: Distance control
Set motor type F1-25 Motor type 1 1
0: Asynchronous motor
1: Synchronous motor
Set motor
parameters
Motor Nameplate
Be sure that motor parameters are set correctly. Otherwise, faults will occur.
F1-01 Rated motor power Model dependent
Unit: kW
F1-02 Rated motor voltage Model dependent
Unit: V
F1-03 Rated motor current Model dependent
Unit: A
F1-04 Rated motor frequency Model dependent
Unit: Hz
F1-05 Rated motor speed Model dependent
Unit: RPM
Set encoder
parameters
F1-00 Encoder type 0
0: SIN/COS encoder
1: UVW encoder
2: ABZ encoder
3: Endat absolute encoder
Set F1-00 according to the actual encoder type.
F1-12
Encoder pulses per
revolution
2048
Set this parameter according to the encoder nameplate.