- 90 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
These parameters are used to monitor the state of all I/O terminals of the system.
The segments of the ve LEDs displayed are dened as follows.
Figure 4-7 Monitoring of all I/O terminals
5 4 3
2
1
A
B
C
D
E
F
G
DP
Note:
1. Segments of LEDs 2 to 5 are marked in the same way as those of LED 1.
2. Segment ON: signal active
Segment OFF: signal inactive
LED No.
F5-34 Terminal state display
1 2 3 4 5
A - Inspection signal
Up slow-down 1
signal
Door machine 1
light curtain
Reserved
B Up leveling signal Inspection up signal
Down slow-down 1
signal
Door machine 2
light curtain
RUN contactor
output
C
Down leveling
signal
Inspection down
signal
Up slow-down 2
signal
Brake contactor
feedback 2
Brake contactor
output
D Door zone signal
Fire emergency
signal
Down slow-down 2
signal
UPS input
Shorting door lock
circuit contactor
control
E
Safety circuit
feedback 1
Up limit signal
Up slow-down 3
signal
Elevator lock input
Fire emergency
oor arrival signal
F
Door lock circuit
feedback 1
Down limit signal
Down slow-down 3
signal
Safety circuit
feedback 2
-
G
RUN contactor
feedback
Overload signal
Shorting door lock
circuit contactor
feedback
PMSM self-lock
feedback
-
DP
Brake contactor
feedback 1
Full-load signal
Fireghter running
signal
Door lock circuit
feedback 2
-