Fault Reset
14
Start Process
Fault Symptom
Cause
Check method
FunIN.2 ALM‑RST
Fault/Warning reset
signal
The servo drive may, depending on
the warning types, continue
running after warning reset. When
FunIN.2 is assigned to a low‑speed
DI, the effective level change of this
DI must be kept for more than 3
ms. Otherwise, fault reset will be
inactive. Do not assign FunIN.2 to a
high‑speed DI. Otherwise, fault/
warning reset will be inactive.
Inactive: Not resetting the
fault/warning
Active: Resetting the fault/
warning