Description of Fault Codes
72
Cause
Troubleshooting
Solution
3. The motor is stalled due
to mechanical factors.
Check the reference and
motor speed (H0b.00)
through the software tool or
keypad.
References in the position
control mode: H0b.13
(Input position reference
counter)
References in the speed
control mode: H0b.01
(Speed reference)
References in the torque
control mode: H0b.02
(Internal torque reference)
Check whether the reference
value is not 0 but the motor
speed is 0 rpm in the
corresponding mode.
Rectify the mechanical‑
related problem.
The servo drive gain is too
low.
Check the position loop gain
and speed loop gain of the
servo drive.
1st gain set: H08.00...H08.02
2nd gain set: H08.03...H08.05
Adjust the gain values
manually or perform gain
auto‑tuning.
5. The position reference
increment is too large.
Position control mode:
In CSP mode, check the
gear ratio 6091.01h/
6091.02h to determine the
position reference
increment for an individual
synchronization period and
convert it to the speed
information.
In PP mode, check the gear
ratio 6091.01h/6091.02h
and determine the 6081h
(Profile velocity).
In HM mode, check the
gear ratio 6091.01h/
6091.02h, and determine
6099.01h and 6099.02h.
CSP: Decrease the position
reference increment per
synchronization period.
The host controller should
cover the position ramp
when generating
references.
PP: Decrease the value
6081h or increase the
acceleration/deceleration
ramp (6083h, 6084h).
HM: Decrease 6099.01h and
6099.02h or increase the
acceleration/deceleration
ramp (609Ah).
Decrease the gear ratio
according to actual
conditions.