EasyManua.ls Logo

Inovance SV670P Series - Page 15

Inovance SV670P Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Reset
14
Start Process
Fault Symptom
Cause
Confirming Method
FunIN.2 ALM‑RST
Fault/Warning reset
signal
The servo drive may, depending on
the warning types, continue
running after warning reset. When
FunIN.2 is assigned to a low‑speed
DI, the effective level change of this
DI must be kept for more than 3
ms. Otherwise, fault reset will be
inactive. Do not assign FunIN.2 to a
high‑speed DI. Otherwise, fault/
warning reset will be inactive.
Inactive: Not resetting the fault/
warning
Active: Resetting the fault/
warning