Warnings!
15kg
30kg
50kg
For devices ≥ 15 kg, it requires at least 2 people.
For devices ≥ 30 kg, it requires at least 3 people.
For devices ≥ 50 kg, it requires at least 4 people.
请保留本文档,以便于日后查阅
Watch out for the scratches that may be caused by the cabinet, chassis or rails.
Be aware of electric shock when installing the servers into the cabinet in use.
DO NOT block the vents on the server during installation, especially the vents on
the front and rear of the server.
Remove the protective film from the chassis before installing servers into the rack.
For proper ventilation, leave a minimum space of 15 cm between two servers.
For easy access of the front and rear ports and cabling, leave a minimum space of
70 mm between the front side of the server and the inner side of the cabinet’s front
door, and 150 mm between the rear side of the server and the inner side of the
cabinet’s rear door.
Always keep the air baes in place to ensure proper air flow and avoid air
turbulence in the server room.
Installation must comply with local and regional electrical regulations. To reduce
the risk of personal injury, fire, or damage to the server, DO NOT overload the AC
supply that provides power to the rack.
Servers can only be deployed in dedicated cabinets with ventilation holes or
specialized cooling cabinets to avoid server failure from overheating as they are
high power appliances.
In case of multiple-server deployment, always load from bottom to top and place
the heavier server on the lower bay.
DO NOT install devices beyond the cabinet’s load-bearing capacity, power supply
capacity and heat dissipation capacity.
Rack-Mounted Server
Installation Guide
V1.0
Question and Answer IconNeed help?

Do you have a question about the Inspur NF5468M6 and is the answer not in the manual?

Summary

General Safety Warnings and Precautions

Installation Safety Guidelines

Covers warnings about scratches, electric shock, blocking vents, protective film, server spacing, access clearance, air baffles, electrical regulations, AC supply, dedicated cabinets, and server placement.

Personnel Requirements for Server Installation

Specifies the minimum number of people required based on server weight: 2 people for >= 15 kg, 3 people for >= 30 kg, and 4 people for >= 50 kg.

Installing the Rails to the Rack

Attaching Rails to Rack

Detailed steps for aligning and securing the rear bracket, front bracket, and inner rails to the rack, ensuring proper engagement and locking.

Rack Rail Installation Alignment

Instructions for repeating rail installation for the other side and notes on ensuring both rails are installed at the same height.

Installing the Server to the Rack

Server Rail Preparation

Steps to fully extend the inner rail and remove it using the locking tab for server mounting.

Mounting Server in Rack

Guidance on aligning the server's inner rails to the rack's middle rails and sliding the server into the rack, followed by securing with captive screws.

Installing Server Rails and Server

Front and Rear Rail Installation

Instructions for installing the front end of the rail to the rack and the rear end of the rail to the cabinet, ensuring level placement and secure locking.

Server Mounting Procedure

Steps to place the server's rear end on the rails first, push it into the rack, and then tighten the screws on the server's ears.