SCHEMATIC DIAGRAMS-25
PRIMARY POWER SUPPLY (PRE) SECTION
PR-SC5508, DHC-80.2
+12V
POFF
MPOWER
APOWER2
+SUB
GNDSUB
+12V
MPOWER
+12V
POFF
APOWER2
APOWER1
+SUB
GNDSUB
2
3
1
6
7
8
9
10
11
12
13
5
6
7
8
9
4
1
3
2
8
7
6
5
4
1
3
2
(VH)
*
TO TRANS
TO TRANS
TO TRANS
(VH)
*
(VH)
(VH)
0.04A
*
PS(Primary PS stage) SECTION
OTHER:2200/16(VR)
D:2200/25(VR)
C9001
MKP R46 104M
J9001
P9008A
OHTER:NPT-1520GQ
D,J:NPT-1520JQ
T9000
MODEL
JL901:7J150606B15
P1.5X7 L=15
Informal name
DHC
*
*
THERMAL FUSE
S1
TUNER,FAN
S3
S2
ASP
BALANCE
S9000
P9008
*
(VH)
(VH)
*
*
(VH)
*
1SS133
1SS133
*
**
SCHEMATIC DIAGRAM (PART-25)
(NO USE)
(NO USE)
RE275-103M
RE275V-103M
275V
T903
T904
*
S7
S6
S4
FLAC
-VP
THERMAL FUSE THERMAL FUSE
*
Small Transformer NPT-1582
HDMI
SP RELAY
DG,
S2
S3
ANALOG VIDEO
12VTRIGER
Middle Trancsformer NPT-1581
Large Transformer NPT-1558
5507
T901
Model No. PR-SC5508,DHC-80.2
5508MP,MR
P9008B
5508MP,MR
DHC MA=NSAS-3P1760
5508MP,MR=NSAS-6P1675
5508MP,MR/DHC MA
DD/JJ
DHC-80.2
PR-SC5508
PR-SC5508,DHC-80.2 Transformer
P6500
P2000
P9301A
*
COLD
HOT
*
LIVE
COLD
HOT
P991
P9000
JJ: 3P
Except JJ: 2P
WHITE #18 L=15
BLACK
1F999028UL
FASTON AS
#18 L=15
P9006
NEUTRAL
D9007
MTZJ5.1B
1
2
P9300
NPLG-2P632
1
2
P9200
NPLG-2P632
1
2
P9100
1
2
ARE CRITICAL FOR SAFETY.
REPLACE ONLY WITH PART NUMBER SPECIFIED.
THE COMPONENTS IDENTIFIED BY MARK
VOLTAGE(MEASURED WITH VOLTMETER)IS DC VOLTAGE.(NO INPUT SIGNAL)
ELECTROLYTIC CAPACITORS(
+
)ARE IN F/WV
ALL CAPACITORS ARE IN pF/50WV UNLESS OTHERWISE NOTED.
EX) 030 3pF 330 33pF 331 330pF 333 0.033 F
CIRCUIT IS SUBJECT TO CHANGE FOR IMPROVEMENT.
THAT THE FUSE USED IS SLOW OPERATING TYPE
RATING REFER TO THE MAKING ADJACENT TO THE SYMBOL.
THIS SYMBOL LOCATED NEAR THE FUSE INDICATES
FOR CONTINUED PROTECTION AGAINST FIRE FUSE
HAZARD,REPLACE WITH SAME TYPE FUSE. FOR FUSE
CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST
A LENT, E POUR UNE PROTECTION PERMANENTE,N'UTILISER
QUE DES FUSIBLES DE MEME TYPE. CE DARNIER EST
INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE.
AV
CAUTION
AND RATING INDICATED.
ONLY WITH FUSE OF SAME TYPE
AGAINST FIRE HAZARD, REPLACE
FOR CONTINUED PROTECTION
CAUTIONF
AFIN D'ASSURER UNE PROTECTION
PERMANENTE CONTRE LES RISQUES
D'INCENDIE, REMPLACER UNIQUEMENT
PAR UN FUSIBLE DE MEME TYPE
ET CALIBRATION COMME INDIQUE.
ATTENTION
VA
P9008A
NPLG-2P631
2
1
C9002
4.7/50(UTSP)
C9008
100/25(UTSP)
+
Q9101
2SC1815-GR
R9108
100K
D9101
1SS133
R9107
1K
J9001
TA_7.5_DIM
JL901A
NSCT-7P878
1
2
3
4
5
6
7
D9005
1SS133
D9000
1SS133
D9001
1SS133
D9003
1SS133
D9002
1SS133
R9005
27
J9102
TA_5.0_DIM
C9108
R9109
180
RL9101
NRL-1P5A-DC9-179
4
3 2
1
T9000
4
3
2
1 9
8
7
6
5
R9202
100
RL9200
NRL-1P5A-DC9-179
4
3 2
1
D9200
1SS133
Q9200
2SC1815-GR
R9200
1K
R9201
100K
C9200
C9101
S9000
NPS-111-L590P
P9008B
NPLG-2P631
2
1
C9001
+
D9009
1SS133
D9006
1SS133
D9010
D9011
E9000
NEJITANSI_ST3
2341
D9008
1SS133
D9004
1SS133
E9100
NEJITANSI_ST3
2341
C9116
103J
C9119
223J
C9000
223J
C9201
103J
AC_CABLE
P9007A
P9006A
P9000
AC INLET
1
2
U0021
BAPS-0243
U0069
BASW-0143
A
1
2
3
4
5
BCDEFGH
TO BAVD-0203
PART-112:K2
TO BAPS-0182
PART-8:A5
TO BAVD-0203
PART-12:K8
TO BAPS-0140 PART-19:A2
TO BAPS-0126 PART-21:A2