Do you have a question about the Integra MAYFIELD and is the answer not in the manual?
Explains hazards associated with caution and warning symbols for equipment damage or personal injury.
Covers symbols for regulatory compliance, manufacturer, representative, restricted use, and product identification.
Describes the system and specifies limitations for pediatric use, requiring caution.
Details inspection requirements and lists critical safety warnings, including MR environment use and device alteration.
Guides on mounting the Coupler to the Base Unit and O.R. Table, including loosening post screws and securing.
Guides on locking the Base Unit handles, sliding the Coupler, and adjusting lateral positions via the Gear Box.
Explains how to mount the Headrest to the Coupler and position replacement gel pads.
Covers tightening T-knobs, adjusting faceplates, and positioning mini gel pads.
Details the simultaneous application of a Skull Clamp for patients aged 5 and older.
Outlines disassembly, cleaning with detergent, and classifies components into Group 1 (Headrests) and Group 2 (Gel Pads).
Warns against immersing gel pads in liquid or heat, and prohibits steam sterilization due to potential damage.
Provides detailed step-by-step instructions for manual cleaning using neutral pH enzymatic detergent and soft bristle brushes.
Explains the process for automated cleaning and disinfection, including cautions on detergent and water quality.
Recommends annual device inspection/servicing, bi-annual routine inspections, and lubricating metal movable parts.
Instructs users to follow hospital procedures for the disposal of the device.
Outlines the one-year warranty against manufacturing defects and limitations on liability and implied warranties.
Provides contact information and instructions for obtaining service and repair within and outside the United States.
Explains hazards associated with caution and warning symbols for equipment damage or personal injury.
Covers symbols for regulatory compliance, manufacturer, representative, restricted use, and product identification.
Describes the system and specifies limitations for pediatric use, requiring caution.
Details inspection requirements and lists critical safety warnings, including MR environment use and device alteration.
Guides on mounting the Coupler to the Base Unit and O.R. Table, including loosening post screws and securing.
Guides on locking the Base Unit handles, sliding the Coupler, and adjusting lateral positions via the Gear Box.
Explains how to mount the Headrest to the Coupler and position replacement gel pads.
Covers tightening T-knobs, adjusting faceplates, and positioning mini gel pads.
Details the simultaneous application of a Skull Clamp for patients aged 5 and older.
Outlines disassembly, cleaning with detergent, and classifies components into Group 1 (Headrests) and Group 2 (Gel Pads).
Warns against immersing gel pads in liquid or heat, and prohibits steam sterilization due to potential damage.
Provides detailed step-by-step instructions for manual cleaning using neutral pH enzymatic detergent and soft bristle brushes.
Explains the process for automated cleaning and disinfection, including cautions on detergent and water quality.
Recommends annual device inspection/servicing, bi-annual routine inspections, and lubricating metal movable parts.
Instructs users to follow hospital procedures for the disposal of the device.
Outlines the one-year warranty against manufacturing defects and limitations on liability and implied warranties.
Provides contact information and instructions for obtaining service and repair within and outside the United States.
| Product Type | Skull Clamp |
|---|---|
| Patient Population | Adult and Pediatric |
| Manufacturer | Integra LifeSciences |
| Sterilization Method | Autoclave |
| Number of Skull Pins | 3 |
| Sterilization | Reusable, sterilizable |
| Compatibility | Compatible with Mayfield headrest systems |
| Material | Stainless Steel |
| Weight | Varies by model |