Enterprise Platforms and Services Marketing Monthly Specification Update
Contents
Preface ....................................................................................................................................... 1
Summary Tables of Changes ................................................................................................... 2
Errata ......................................................................................................................................... 4
1. Errors are reported during the installation of SuSE SLES 10 EM64T ..................... 4
2. Hyper Threading cannot be disabled in BIOS setup ............................................... 4
3. A critical interrupt is logged in the System Event Log (SEL) when installing SuSE
SLES 10 32 bit ......................................................................................................................... 4
4. Serial Console mode may display extra text or intermingled text ............................ 4
5. The PXE boot option is missing in BIOS Setup ...................................................... 5
6. Fans may boost temporarily when BMC is under load ............................................ 5
7. Extra events may be seen in the SEL during system reset ..................................... 5
8. BIOS setup may report an incorrect firmware version ............................................ 6
9. Excessive Time to Enter or Exit EFI Shell When AHCI is Enabled in BIOS
Revision R0037 ....................................................................................................................... 6
10. Must use software package with BIOS36/FW36/FRUSDR13 or later when using
4GB memory modules in the SR1630BC ................................................................................. 6
11. Serial Over LAN (SOL) Will not Automatically Enable Console Redirection When
Console Redirection Is Disabled In BIOS Setup ...................................................................... 7
12. Under Red Hat* Linux 5.3 when in SATA MODE to Compatibility Mode the
installation process may take over an hour .............................................................................. 7
13. Excessive logs get reported after system reboot when running SuSE* Linux 10,
with Service Pack 2 x86 ........................................................................................................... 8
14. System hang may occur during FRU/SDR update process with the Intel® Server
System SR1630BC .................................................................................................................. 8
15. System May Not Configure to CLTT Mode when using Unbuffered Memory with
Thermal Sensors ..................................................................................................................... 8
16. Clearing BIOS CMOS in BIOS Revision R0042 May Return an Invalid Date .......... 8
17. Intel® Active System Console (IASC) 3.5.1 and 3.5.2 may fail to detect status of
memory voltage sensors .......................................................................................................... 9
18. SuSE* SLES11 kernel may halt for 60~150seconds during installation with default
BIOS setting ............................................................................................................................ 9
19. BIOS setup may report inaccurate HSC FW revision ........................................... 10
20. System fail in booting into SuSE* SLES11 32 bit Xen Kernel when memory
size >=4GB under SW RAID mode ........................................................................................ 10
21. System with BIOS Revision R0054 may hang when Adaptec* 5405 or 5805 RAID
card installed. ........................................................................................................................ 10