Enterprise Platforms and Services Marketing Monthly Specification Update
2
Summary Tables of Changes
The following tables provide an overview of known errata and known document changes that
apply to the specified Intel Server Products. The tables use the following notations:
Intel intends to update the appropriate documentation in a future revision.
Intel intends to correct this erratum.
This erratum has been corrected.
There are no plans to correct this erratum.
This item is new or has been modified from the previous specification update.
Table 1. Errata Summary
No.
Plans
Description of Errata
1.
Fix
Errors are reported during the installation of SuSE SLES 10 EM64T.
2.
Fixed
Hyper Threading cannot be disabled in BIOS setup.
3.
NoFix
A critical interrupt is logged in the System Event Log (SEL) when installing SuSE SLES 10 32 bit.
4.
Fixed
Serial Console mode may display extra text or intermingled text.
5.
Fix
The PXE boot option is missing in BIOS Setup.
6.
Fixed
Fans may boost temporarily when BMC is under load.
7.
Fixed
Extra events may be seen in the SEL during system reset.
8.
Fixed
BIOS setup may report an incorrect firmware version.
9.
Fixed
Excessive Time to Enter or Exit EFI Shell When AHCI is Enabled in BIOS Revision R0037.
10.
Fixed
Must use software package with BIOS36/FW36/FRUSDR13 or later when using 4GB memory
modules in the SR1630BC.
11.
Fix
Serial Over LAN (SOL) Will not Automatically Enable Console Redirection When Console Redirection
Is Disabled In BIOS Setup.
12.
Fix
Under Red Hat* Linux 5.3 when in SATA MODE to Compatibility Mode the installation process may
take over an hour.
13.
Fix
Excessive logs get reported after system reboot when running SuSE* Linux 10, with Service Pack 2
x86.
14.
Fixed
System hang may occur during FRU/SDR update process with the Intel
®
Server System SR1630BC.
15.
Fixed
System May Not Configure to CLTT Mode when using Unbuffered Memory with Thermal Sensors.
16.
Fixed
Clearing BIOS CMOS in BIOS Revision R0042 May Return an Invalid Date.
17.
Fix
Intel
®
Active System Console (IASC) 3.5.1 and 3.5.2 may fail to detect status of memory voltage
sensors.
18.
NoFix
SuSE* SLES11 kernel may halt for 60 ~ 150 seconds during installation with default BIOS setting.
19.
Fix
BIOS setup may report inaccurate HSC FW revision.
20.
NoFix
System fail in booting into SuSE* SLES11 32 bit Xen Kernel when memory size >=4GB under SW
RAID mode.

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals