Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  27 
High current electronic output, rating: 1 A at 13.8 V 
Low current electronic output, rating: 50 mA at 13.8 V 
[1]  Maximum cable length for low current output connection may not exceed 30 m. For longer 
distances, use relay output expansion (for example, ATS624 four-relay expander).  
Tested temperature according 
EN 50131 
See “List of panel variants” on page vi 
ATSx000A(-IP): Grade 2, Class II 
Enclosure (meets UL94V-0) 
Maximum altitude, or minimum air 
pressure 
2000 m above mean sea level 
Siren 1, high current output S1 
Siren 2, high current output S2 
Note: Mains fuse is part of the mains terminal block. 
WARNING: Before removing the mains fuse, mains power must be disconnected 
(see “Mains power connection” on page 8).