Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  83 
Users 
3.1 Users 
 
The Users menu lets you add, delete and edit system users. 
Note: If the system is EN 50131 compliant, you can edit only your own settings, 
and configure only newly added users. See “User data lock” below for more 
details. 
For each user, the system records these options: 
•  Number (a panel ID number between 1 and 50) 
•  Name 
•  PIN 
•  Card ID number 
•  User group (which determines options the user can access) 
•  Language 
Note: Your own user group might not allow you to program PINs. If it does allow 
use of this option, there might still be restrictions on which user groups you are 
allowed to update. 
Predefined users 
There are two users predefined in the system: 
•  Installer is used to enter the Advisor Advanced system configuration. He has 
user group “Installer group” assigned. 
•  A user with default name Supervisor who can grant access to the installer 
menu for the service engineer. He has user group “Supervisor group” 
assigned. The default supervisor PIN is 1122. 
Note: If the configured PIN length is configured for more than 4 digits, zeroes are 
added to the default PIN values. For example, if the system is configured for 6-
digit PINs, the supervisor PIN is 112200. 
There is always one installer in the system. More than one user can have rights 
that allow granting access to the installer or service engineer. 
For more information see “3.2 User groups” on page 89. 
User data lock 
When a system is configured as EN 50131 compliant, you are not allowed to 
modify settings for an existing user (other than yourself). A new user can be 
configured only when added, and an existing user can only be removed. The 
installers can only modify their own settings, and the other users can modify their 
own settings via user menus (see Advisor Advanced User Guide and Advisor 
Advanced Manager Manual for more details).