54  Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 
1.2.5.3 Single zone WT 
 
Before walk test starts, you are asked if the reporting to central stations must be 
enabled (see “1.2.5.1 Walk test start” on page 51 for details). 
Select the input location first (panel, internal or external expander). Then enter 
the (physical) input number on this location. 
Proceed with walk test for this particular zone the same way as for all zones in a 
standard walk test. See “1.2.5.1 Walk test start” on page 51. 
1.2.5.4 Special WT mode 
 
A special walk test mode allows verification of the whole alarm system 
functionality. In this mode, a service engineer or a guard must perform as many 
actions on the operating alarm system as possible. This may include set and 
unset, entry and exit, activating all detectors and tampers. The system operates 
as usual, sending all alarm and tamper events to the central station, except none 
of system sirens is active. 
This allows the central station operator to review all received alarms and verify if 
appropriate system functions are working properly. 
1.2.6 Test call opts 
 
The Test call menu allows you to define the automatic test call interval, and to 
perform a test call on demand. 
1.2.6.n Select central station 
 
1>Test call mode 
2 Period 
Select central station to configure test call options. 
1.2.6.n.1 Test call mode 
 
Choose one of the following modes for the automatic test call. 
•  Off: Automatic test call is disabled. 
•  Period: Automatic test call recurs at defined intervals.  
•  Time: Automatic test call occurs every day at a specified time.