LED Keypad

Time Hour Code
Time Hour Code
Time Hour Code
12:00
Midnight
00
8:00 AM 08
4:00 PM 16
1:00 AM 01
9:00 AM 09
5:00 PM 17
2:00 AM 02
10:00 AM 10
6:00 PM 18
3:00 AM 03
11:00 AM 11
7:00 PM 19
4:00 AM 04
12:00 Noon 12
8:00 PM 20
5:00 AM 05
1:00 PM 13
9:00 PM 21
6:00 AM 06
2:00 PM 14
10:00 PM 22
7:00 AM 07
3:00 PM 15
11:00 PM 23
SETTING THE KEYPAD LIGHTING
1.
Press [
7
]-[
9
]-[
1
]. The
service
light
will flash.
2.
Press the [
1
] and [
2
] keys to lighten or darken the illumination behind the
buttons. It is usually easier to set this adjustment in a darkened room.
SERVICE MENU
The
service light
will be on if the security system requires service. If the
service light
is on, press [
7
]-[
2
] to determine the service condition. One or more zone lights will
illuminate indicating what service(s) is required. Call your service provider immediately
for these problems. Below is a listing of what each light means in a service condition.
LIGHT PROBLEM
SYSTEM FAULT -
Press [
1
]. The
zone light(s)
that is illuminated
corresponds to the system fault(s) below:
1
Over Current Fault
2
Siren Trouble
3
Box Tamper
4
Expander Power
5
Expander Low Battery
6
Expander Box Tamper
7
Expander Trouble
8
Ground Fault
1
Note: Faults 1 & 2 are global in nature and will affect all partitions of a multi-
partition system. Press [#] to return to the 1 of 8
service lights
.
2 ZONE TAMPER -
Press [
2
] and the
zone light(s)
will illuminate showing the
zone(s) that are tampered. Press [
#
] to return to the 1 of 8
service lights
.
3 ZONE LOW BATTERY -
Press [
3
]. The
zone light(s)
will illuminate showing
which zone(s) has a low battery. This only applies to wireless zones. Press
[
#
] to return to the 1 of 8
service lights
.
4 ZONE LOSS OF SUPERVISION -
Press [
4
] and the
zone light(s)
will
illuminate showing which zone(s) has loss of supervision. This only applies
to wireless zones. Press [
#
] to return to the 1 of 8