PIR Camera Reference Manual 5
The wireless expander is powered from the Advisor Advanced control panel MI
bus.
Installation
ATS1238 is mounted inside Advisor Advanced large plastic housing.
WARNING: Electrocution hazard. To avoid personal injury or death from
electrocution, remove all sources of power and allow stored energy to discharge
before installing or removing equipment.
Refer to ATS1238 Advanced Wireless DGP Installation Sheet for details on
installation and address setting.
Programming
The ATS1238 expander is programmed using the Advisor Advanced control
panel programming menu. Refer to Advisor Advanced Programming Manual for
details.
To activate the expander, use the Devices submenu of the Advisor Advanced
programming menu. See Programming menuson page 7 for details.
Wireless PIR camera
Description
A wireless PIR camera is a wireless PIR detector with a camera built-in. The
camera can be programmed to take pictures in case of activation of associated
zones, conditional filters, as well as by manual activation or remote requests.
See “Camera activationon page 2 for more details.
Installation
The PIR camera is intended to be mounted on walls but can also be mounted on
ceilings by using a mounting bracket.
Use the following guidelines to determine the best location to install the PIR
camera.
Mount the PIR camera so the expected movement of an intruder is across the
detection pattern.
Mount the PIR camera at a stable surface at a height between 1.8 m and
3.0 m from the floor.
Do not mount the PIR camera within 0.5 m of metallic objects or within 1.5 m
of fluorescent lights.
Do not place objects in front of the PIR camera that may prevent a clear line
of sight.
Place PIR cameras at least 1 m apart from each other.
Avoid potential causes of instability, such as:
Direct sunlight on the detector