6 EasyLAN Ethernet Software Instructions
Setting Network Parameters from the
Printer Home Page
You can change all network parameters by using your web
browser to access the printer home page. To access the home
page, you need the IP address of the printer. As a default setting,
the printer is set to automatically receive an IP address from the
network, but communication will only work if the network is
also set to assign IP addresses automatically through DHCP or
BOOTP.
There are four different methods for setting the IP address of the
printer. DHCP, BOOTP, and DHCP+BOOTP allows the server
to assign the printer a temporary IP address, and also sets the
netmask, default router and name server automatically. If the
server neither supports DHCP nor BOOTP, or if you want to set
a permanent IP address manually, you can use the MANUAL
option. In this case, you also have to set the netmask, default
router, and name server manually.
If you have problems accessing the printer home page, use one of
the other methods described in these instructions to set the
printer network parameters.
To access the printer home page
1 Use an Ethernet cable to connect the printer to your network.
2 Print test labels from startup (for help, see the EasyCoder
PD41 Printer Users Guide (P/N
1-960652-xx)).
The IP address of the printer is printed on the “Network
settings” test label.
3 Enter the IP address in the address field of your web browser.
The printer web page opens.

Other manuals for Intermec EasyCoder PD41

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PD41 and is the answer not in the manual?

Intermec EasyCoder PD41 Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Power requirements100-240 VAC ±10%, 45-65 Hz
Media thickness2.3 - 9.8 mm
Maximum label width104 mm
Maximum label length0.15 m
Maximum roll diameter213 mm
Maximum internal memory1 GB
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)20 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth453 mm
Width273 mm
Height270 mm
Weight13000 g