Boot Terminal
Purpose: Boots the terminal. The terminal runs through power-on self test (POST) to test each
major subsystem. The terminal uses the configuration currently saved in flash memory to
boot and then your application appears on the screen.
Use this command when you upgrade the firmware on the terminal or if your terminal
locks up and will not respond.
From Network: -.1
Scan:
Boot Terminal
*-.1*
*-.1*
Change Configuration
Purpose: This command must precede any configuration command. If you enter a valid string, the
terminal configuration is modified and the terminal sounds a high beep. For help on the
configuration commands, see Chapter 9, “Configuration Command Reference.”
From Network: $+
command[command]...[command n]
where
command
is a configuration command with the value you want to set.
Keypad: Press
T3,
to access the TRAKKER Antares 2400 Menu System. From the
Main Menu, choose the Configuration Menu to change the terminal’s configuration.
Example:
Change Configuration / Turn Off Beep Volume
*$+BV0*
*$+BV0*
The Change Configuration command is followed by the configuration command to turn
off the beep volume (BV0).