UDM108-01 19 RSA2024-TB/2”
Troubleshooting
Interpack Carton Sealers are fabricated with high quality components that provide trouble-free
operation for a long period. However, if a problem should occur we recommend that you always
look for simple things first, then more complex problems. This is exactly how this table is
constructed, as the numbers increase, complexity increases.
TROUBLE
POSSIBLE CAUSES SOLUTIONS
The main power
is turned on and
nothing happens
1- One of the fuses is burned.
1- Verify all fuses in the electric
box.
The machine is
ON but the
Infeed Guides do
not center the
carton on the
Infeed Table.
1- Compressed air supply is not
connected.
2- The air tubing or the valve is
obstructed or defective.
1- Inspect air connection and
operating pressure
2- Inspect the air tubing and the
valve for leaks or obstructions.
The Infeed
Guides closes
when the
machine is
powered up even
when there is no
carton on the
Infeed Table.
1- The Infeed Table’s Sensor is
not aligned with his reflector.
1- Check the alignment of the
Infeed Sensor with his reflector.
The Top Belt
Drive Assembly
stays up or goes
down too slowly.
1- The High Flow Pressure
Regulator is adjusted too
high.
1- Reduce the air pressure setting
of the High Flow Pressure
Regulator, located at the infeed
end of the machine, under the
left hand Side Cover.
The Top Belt
Drive Assembly
goes down too
quickly or
crushes the
carton.
1- The High Flow Pressure
Regulator is adjusted too low.
1- Increase the air pressure setting
of the High Flow Pressure
Regulator, located at the infeed
end of the machine, under the
left hand Side Cover.