EasyManua.ls Logo

Interpack USA 2024-SB - Page 18

Interpack USA 2024-SB
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UM094TW / UM594TW UDM094-04
18
SPECIFICATIONS
1. Operating Conditions
Use in a dry, relatively clean environment at 40° to 105° F (5° to 40° C) with clean dry
cartons.
Note: Machine should not be washed down or subjected to conditions
causing condensation on components.
2. Power Requirements
Electrical - 115 VAC, 60 HZ, 5.0 A (560 Watts)
Compressed Air – N/A
This machine comes standard with two gear motors, one on each drive base and an
electrical box.
The electrical box contains a Start switch, the Emergency Stop switch, and a starting
relay with a thermal over load. An eleven foot (11’) standard three conductor power cord
with plug is provided for 115V, 60HZ, 15 Amp service. The receptacle providing this
service must be properly grounded.
3. Operating Speed
Actual production rate is dependent on operator’s dexterity and the case size mix.
Boxes must be 14 inches apart. Belt Speed is 82 Ft/min.
Figure-5
0
10
20
30
40
50
60
6 8 10 12 14 16 18 20 22 24 26 28 30
CasesPerMinute
CaseLength(Inches)
CasesPerMinuteByCaseLength