4. Each lighting unit needs to have a DMX address to receive the data by the controller. The
address number is between 1-512.
5. The end of the DMX 512 system should be terminated to reduce signal errors.
6. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.
6. Error Information
1. Pan Reset Error
Check if the position of the pan mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the pan operating range.
Check if the pan Hall elements is damaged.
Check if the pan Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the pan motor is damaged.
Check if there is any damage to the circuit of the pan motor drive board.
2. Pan Encoder Error
Check if the pan encoder is damaged.
Check if the pan encoder is in poor contact with the lead of the PCB board or disconnected.
3. Tilt Reset Error
Check if the position of the tilt mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the tilt operating range.
Check if the tilt Hall elements is damaged.
Check if the tilt Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the tilt motor is damaged.
Check if there is any damage to the circuit of the tilt motor drive board.
4. Tilt Encoder Error
Check if the tilt encoder is damaged.
Check if the tilt encoder is in poor contact with the lead of the PCB board or disconnected.