3.3.1 MINIMUM CLEARANCES (continued)
Mantle Height
from Floor (Y)
Mantle Depth (X)
40" 10"
39" 9"
38" 8"
37" 7"
36" 6"
34" 5"
33" 4"
Minimum Clearances to Combustibles
A – Internal Ceiling 48” (1219 mm) from floor
B– Back & Sidewalls 0" (0 mm) with 1” (25 mm) Standoffs installed
Mantle (see chart)
D --Internal Framing 34-7/8” (886 mm) from floor to bottom edge of framing
E --Unit Trim to sidewall 6” (152 mm)
F - Floor 0” (0 mm)
Note: Check local codes for floor requirements.
This fireplace is suitable for installation on a combustible surface.
“Clearances are in accordance with local installation codes and the requirements of the gas supplier.”
**The mantel placement chart on the previous page illustrates the allowable mantel sizes and
placements. The 1” incremental grid can be used to determine the allowable mantel size based on
the elevation above the units upper trim.
When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant
(up to 250º F) to prevent discolorations.