1.2 FEATURES
Ignition system:
Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter.
Gas control:
Gas control valve type:
Automatic millivolt powered combination gas control valve with variable flame control for
convenience and on/off switch. Optional digital remote on/off wall switch and/or optional wall
thermostat (note: thermostats are not allowed in the United States). The gas valve does not
require electricity from an external source.
Fan control * Optional *
Variable speed control:
For units equipped with a fan control, the knob controls the fan speed, turning the knob
counter-clockwise turns it to the “Off” position.
1.3 INTENDED USE
This appliance is intended to be used as a zero clearance fireplace. This unit is certified for
installation in a bedroom or a bed sitting room where the maximum input is within 50 cubic feet per
1000 Btu/hr, (i.e. 900 cubic feet for E unit & 1600 cubic feet for H unit). In Canada all bedroom
installations require the use of wall thermostats (note: thermostats are not allowed in the United
States).