1.0 INTRODUCTION
1.1 SPECIFICATIONS
TABLE 1
ITEM NATURAL GAS (NG) PROPANE (LPG)
INPUT: Hi 18,000 Btu/hr (5.27 kW) 15,000 Btu/hr (4.39 kW)
INPUT: Lo 12,500 Btu/hr (3.66 kW) 12,500 Btu/hr (3.66 kW)
MANIFOLD PRESSURE: Hi 3.5” w.c. (0.87 kPa) 10” w.c. (2.49 kPa)
MANIFOLD PRESSURE: Lo 1.7” w.c. (0.42 kPa) 6.4” w.c. (1.57 kPa)
GAS INLET SUPPLY
PRESSURE:
Minimum: 5.0” w.c. (1.2 kPa) Minimum: 12” w.c. (2.99 kPa)
Maximum: 13.5” w.c. (3.4 kPa) Maximum: 14” w.c. (3.49 kPa)
ORIFICE SIZE: @ 0-4500’ # 48 DMS # 57 DMS
CONTROL VALVE TYPE: Honeywell , SIT 820 Nova,
Robertshaw-Grayson or
Skytech AF-4000
Honeywell , SIT 820 Nova,
Robertshaw-Grayson or
Skytech AF-4000
VENTING 2-ply aluminum vent,
Simpson Dura-Vent, Selkirk or
Security
2-ply aluminum vent,
Simpson Dura-Vent, Selkirk or
Security
FAN * Optional * Variable Speed (120 Volt) Variable Speed (120 Volt)