All valves have been pre-set and certified for installation at elevations from 0 – 4500 feet (1 – 1372m)
above sea level.
When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing
the existing burner orifice with a smaller size for installations over 4500 feet (1372m). The appliances
input should be reduced 4% for each additional 1000 feet (305m) above sea level. For the USA, de-
rate the unit from sea level according to the gas installation code.