3.3.10 FIELD ASSEMBLED PARTS
OPTIONAL FAN INSTALLATION
The optional fan kit (part # IMC1057A) is available with a 45 mm fan. To install the optional fan you
will need to have 120 VAC run to a receptacle inside the unit. Remove the bottom louver and control
panel then slide the fan kit into place behind the valve and secure with 3 # 10 sheet metal screws in
the holes provided on each side. Plug the fan cord into the receptacle. A thermal snap disk is
provided to turn the fan on after the unit has run for approximately 5 – 10 minutes. The snap disk is
installed by sliding it into the holder on the bottom side of the valve tray. See Figure 2 for electrical
wiring schematic and Figure 17 for fan installation. Replace control panel and bottom louver.