Page 2
(188PO) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013
English
188
PO
S AVE THESE INSTRUCTIONS
English
Page 25
TROUBLESHOOTING GUIDE (continued)
1.Filterpumpnotattachedtosystem
and/or switch on.
2. Circulation line is blocked.
3. Incorrect inlet and outlet hose direction.
4. Scale on the flow sensor.
5.Flowsensorcordisloose.
6. Inner timer conflict between filter pump
and saltwater system.
7.Flowsensorfailure.
1. Dirt or scale on titanium plates.
2. Low salt level / No salt.
3. Electrolytic cell cord is loose.
4. Possible electrolytic cell failure.
1. High salt level.
1. Display and all lights are off - the
system does not power up.
• Ensure filter pump is attached and operating.
See"SetupInstruction".
• If your unit has plunger valves, ensure that
they are open.
• Clear your filter cartridge and cell from debris
and dirt. See “Maintenance”.
• Release all trapped air in the circulation line.
See the filter pump manual.
• Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See
“Set Up Instructions”.
• Clean the flow sensor, paying special attention
to the hinge. See “Maintenance”.
• Plug the flow sensor firmly into the flow sensor
receptacle.
• Reset both timers on the filter pump and
saltwatersystem.See“BoostCycle”.
• Contact Intex Service Center.
• Remove the electrolytic cell for inspection.
Clean it if necessary. See “Maintenance”.
•
Add salt. See “Salt & Pool Water Volumes”.
• Ensure that the cell cord is plugged firmly into
the cell housing receptacle.
• Contact Intex Service Center. Replace the cell
if needed.
• Partially drain the pool and refill it with fresh
water. See “Salt & Pool Water Volumes”.
• Household voltage is too high or too low
(+20%).Checkthevoltageiswithintherange
stated on the device housing.
• Contact Intex Service Center.
LED PANEL
CODE
PROBLEM
SOLUTION
LEDPanelCodeFlash&AlarmOn(NOTE:Alwaysturnoffthepowerbeforecleaningandservicing).
IMPORTANT
If you continue to experience difficulty, please contact our Consumer Service Department for
assistance. See separate “Authorized Service Centers” sheet.