EasyManua.ls Logo

Intex CS7110 - LED Code Chart; Understanding LED Indicators

Intex CS7110
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 2
(188PO) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013
English
188
PO
S AVE THESE INSTRUCTIONS
English
Page 19
LED CODE CHART
LED Reading Definitions
80 BoostMode
00 Stand-ByMode(Start-up)
01 MinimumOperatingHour(1hourremaining)
02 OperatingHours(2hoursremaining)
03 OperatingHours(3hoursremaining)
04 OperatingHours(4hoursremaining)
05 OperatingHours(5hoursremaining)
06 OperatingHours(6hoursremaining)
07 OperatingHours(7hoursremaining)
08 OperatingHours(8hoursremaining)
09 OperatingHours(9hoursremaining)
10 OperatingHours(10hoursremaining)
11 OperatingHours(11hoursremaining)
12 MaximumOperatingHours(12hoursremaining)
90 AlarmCode(LowPumpFlow/NoPumpFlow)
91 AlarmCode(LowSaltLevel)
92 AlarmCode(HighSaltLevel)
93 Stand-ByMode(OperatingProcessfinished)
“BLANK” NoPoweror“PowerSavingMode”waitingtostartnext
Saltwater System cycle.
IMPORTANT
When Code “90” alarm is shown, ensure the timer of the filter pump is set one (1)
hour longer than the Saltwater System.
If the filter pump does not have a built-in timer, the filter pump needs to be turned
on/off manually every day.