TROUBLESHOOTING GUIDE (continued)
1
. Circulation line is blocked.
2
. Incorrect inlet and outlet hose
direction.
3
. Scale on the flow sensor.
4
. Flow sensor cord is loose.
5
. Device is set and operating in
backwash, rinse or waste mode.
6
. Flow sensor failure.
1
. Dirt or scale on titanium plates.
2
. Low salt level / No salt.
3
. Electrolytic cell cord is loose.
4
. Possible electrolytic cell failure.
1
. High salt level.
2
. Possible electrolytic cell failure.
1
. LED display is off and the
“SERVICE” light is on - the system
does not power up.
•
If your unit has plunger valves, ensure
that they are open.
•
Clear your basket and cell from debris
and dirt. See “Maintenance”.
•
Depress the 6-way valve,
r
elease all
trapped air in the circulation line.
•
Check the direction of the inlet and the
outlet hose. Reverse the hoses if
necessary. See “Set Up Instructions”.
•
Clean the flow sensor, paying special
attention to the hinge. See
“Maintenance”.
•
Plug the flow sensor firmly into the flow
sensor receptacle.
• Ignore the alarm, finish the backwash, rinse
or waste operation then turn the power
switch OFF and ON again to reset the alarm.
•
Contact Intex Service Center.
•
Remove the electrolytic cell for
inspection. Clean it if necessary. See
“Maintenance”.
•
Add salt. See “Salt & Pool Water
Volumes”.
•
Ensure that the cell cord is plugged
firmly into the cell housing receptacle.
•
Contact Intex Service Center. Replace
the cell if needed.
•
Partially drain the pool and refill it with
fresh water. See “Salt & Pool Water
Volumes”.
•
Contact Intex Service Center. Replace
the cell if needed.
•
Household voltage is too high or too low
(+ 20%). Check the voltage is within the
range stated on the device housing.
•
Contact Intex Service Center.
LED PANEL
CODE
PROBLEM
SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).