Trouble Shooting Guide
FILTER MOTOR Not plugged in. Filter cord must be plugged into a 3 wire
FAILS TO Fuse box needs checking. outlet that is protected by a Class A
START GFCI circuit breaker tripped. Ground Fault Circuit Interrupter, or RCD.
Reset circuit breaker. If circuit breaker trips
repeatedly, your electrical system may
have a defect. Turn off circuit breaker and
call an electrician to correct the problem.
Motor too hot and overload protection shut
motor off. Let motor cool down.
FILTER DOESN’T Improper chlorine or pH levels. Adjust chlorine and pH level. Consult your
CLEAN POOL Filter cartridge dirty. local swimming pool supply stores.
Cartridge damaged. Clean or replace cartridge.
Excessively dirty pool. Check for holes in cartridge. Replace if
Strainer screen restricting flow. damaged.
Operate filter for longer periods.
Clean strainer screen at pool wall inlet.
FILTER DOESN'T Inlet/discharge clogged. Look for obstructions in intake hose or
PUMP WATER Air leak on intake line. discharge hose inside pool wall.
OR FLOW IS Scale or buildup on cartridge. Tighten hose nuts, check hoses for
VERY SLOW Excessively dirty pool. damage, check pool water level.
Filter cartridge dirty. Replace cartridge.
Clean cartridge more often.
Clean inside plunger valve.
Pull valve handle to full upright position.
PUMP DOESN'T Low water level. Fill pool to correct water level.
WORK Strainer screen plugged up. Clean strainer screens at pool inlet.
Air leak on intake hose. Tighten hose nuts, check hose for damage.
Faulty motor or impeller jammed. Check & clear any sticks or leaves in
Air lock inside cartridge chamber. intake to pump.
Turn & pull valve handle to full upright
position.
TOP COVER O-ring missing. Remove cover & check for O-ring.
LEAKING Cover not tight. Tighten cover (Manually).
Filter cartridge dirty. Replace or clean cartridge.
HOSE LEAKING • Hose nuts. Tighten/reinstall hose nut.
104