EasyManuals Logo

Intex PureSpa SB-H20 Repair Guide

Intex PureSpa SB-H20
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Page 30
Air Blower Problems
Issues with the air can be due to a defective air pump, bad tub, and damaged or missing seals. Problems
with the air pump could also be due to it becoming overheated.
If the Air Blower has failed and no longer turns on:
Verify that the connections for the terminals are not swapped. For example, a Terminal that should be
connected to #7 is connected to #9. Testing the air pump’s voltage on the PCB next. Terminals (7&8) should
be tested with a voltmeter for voltage reading equal the wall voltage. Do this by putting probes to the two
terminals and run the air blower function on the spa.
If the reading on the terminals is ok, change the air blower.
If the reading is on the terminals is not ok, change the PCB
To change the air blower, first access the inside of the Control Base. Release terminals of 7&8 and the
wire leading from the air blower to the grounding box. Release the screws that hold the blower
Yes
No Bubble
No
1. Replace a bubble motor;
2. Or replace a PCB
Go Back to Next Step
END
Run Bubble,
bubble come out?

Other manuals for Intex PureSpa SB-H20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intex PureSpa SB-H20 and is the answer not in the manual?

Intex PureSpa SB-H20 Specifications

General IconGeneral
Control PanelDigital
Air Jets120
BrandIntex
TypeInflatable Hot Tub
Digital Control PanelYes
Seating Capacity4 person
Water Capacity210 gallons
Bubble Jets120
Heating SystemYes
CoverIncluded
Height28 inches
ModelSB-H20

Related product manuals