Mechanical installation4
j | BA 14.0168 | 10/2013
26
Minimum requirements for end shield:
| Material S235 JR , C15 or EN-GJL-250
Consult INTORQ if other materials are to be used.
| Evenness
Size06to12:<0.06mm
From size 14: < 0.1 mm
| Axial runout 0.10 mm,
| Roughness Rz 10 to Rz 16
| Tensile strength Rm > = 250 N/mm
2
| Drill the threaded holes with the minimum thread depth (dimensions 18).
| The end shield must be free of grease and oil.
The diameter of the shaft shoulder must not be bigger than the tooth root diameter of the hub.
4.3 Necessary tools
Type Torque key
Insert for h exagon socket
screws
Wrench size of open-jawed spanner [mm] Hook wrench
DIN 1810
design A
Box spanner
for flange
installation,
outside
*
Manual
release
Measuring
range [Nm]
Wrench size
[mm]
Sleeve b olts Nuts / bolts 2-flat lever Diameter
[mm]
Wrench size
[mm]
BFK458-06
1to12
3x
1
/
4
square
8 7/5,5
7
45 - 55
7x
1
/
2
square
BFK458-08
4x
1
/
4
square
9
10 / 7
52 - 55
8x
1
/
2
square
BFK458-10
5 x 1/4”
square
12
68 - 75
10 x
1
/
2
square
BFK458-12
80 - 90
BFK458-14
20 to 100
6x
1
/
2
square
15
12 / 8 9
13 x
1
/
2
s
q
u
a
r
e
BFK458-16 95 - 100
BFK458-18
-/10
10 110 - 115
square
BFK458-20 12 135 - 145
17 x
1
/
2
square
BFK458-25
8x
1
/
2
square
17 14 155 - 165
* for flange mounting insertion with journal guide
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com