EasyManua.ls Logo

INTORQ BFK-458-12E - Commissioning; During Operation

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning and operation6
i
j | BA 14.0168 | 10/2013
45
6.3 Commissioning
1. Switch on drive system.
2. Carry out a braking test, if necessary, reduce brake torque.
6.4 During operation
Danger!
The running rotor must not be touched.
Danger!
Live connections must not be touched.
| Check the brake regularly during operation. Take special care of:
unusual noises or temperatures
loose fixing elements
the condition of the electrical cables.
| The armature plate must be attracted and the drive must move without residual
torque.
| Measure the DC voltage a t the brake.
Compare the DC voltage measured with the voltage specified on the nameplate. A
±10 % deviation is permissible.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com