RemedyCauseFault
Rotor not thick enough Rotor has not been replaced in time Replace rotor, 51
Voltage is not zero when checking
the operation 41
Incorrect wiring of microswitch Check the wiring of the microswitch and correct it.
Defective microswitch or incorrect
setting
Replace the stator and send the defective stator to
the manufacturer.
Voltage too high Brake voltage does not match the
rectifier
Adapt rectifier and brake voltage to each other.
Voltage too low
Brake voltage does not match the
rectifier
Adapt rectifier and brake voltage to each other.
Defective rectifier diode Replace rectifier by a suitable new one.
AC voltage is not mains voltage
Fuse missing or defective Select a connection with proper fusing.
Incorrect wiring of microswitch Check the wiring of the microswitch and correct it.
Defective microswitch or incorrect
setting
Replace the entire stator and return it to the
manufacturer.