Invacare®Platinum™10L
OxygenConcentrator
IRC10LX
enHomeFill®SystemCompatible
UserManual
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuturereference.

Questions and Answers

  • J
    John DixonAug 2, 2025
    What to do if the red light is illuminated on Invacare Medical Equipment?
    • B
      benjaminkellyAug 2, 2025
      If the red light is illuminated and continuous on your Invacare Medical Equipment, it indicates a system failure. This could be due to the unit overheating because of a blocked air intake, insufficient power at the outlet, or internal repairs being required. Try the following: 1. Remove and clean the cabinet filters or move the oxygen concentrator at least 12 inches away from walls, draperies, or furniture. 2. Avoid using extension cords and try a different electrical outlet or circuit. 3. If the problem persists, contact your service provider.
  • B
    Benjamin SchmidtAug 11, 2025
    Why is the green light illuminated and beeping rapidly on my Invacare Medical Equipment?
    • B
      barbara28Aug 12, 2025
      If the green light is illuminated and you hear rapid beeping from your Invacare Medical Equipment, it signals a potential obstruction. This might be due to an internal obstruction in the oxygen path, such as kinked or blocked tubing, cannula, or humidifier, or the flowmeter might be set at 1.0L/min or less. To resolve this: 1. Check for any kinks or blockages in the tubing and other components. Correct, clean, or replace any affected items. After doing so, turn the power off for 60 seconds and then turn it back on. 2. Ensure the flowmeter is reset to the prescribed flow rate.
  • K
    kathryn60Aug 23, 2025
    How to fix Invacare PLATINUM 10L Medical Equipment with no lights and short beeps?
    • N
      Nicholas RichardsAug 23, 2025
      If no lights are illuminated and you hear short beeps followed by a long pause on your Invacare Medical Equipment, it indicates a main power loss. This could be due to the power cord not being plugged in, no power at the outlet, or a tripped circuit breaker. Here’s what you can do: 1. Ensure the power cord is properly inserted into the outlet. 2. Inspect your house's circuit breakers or fuses. If the problem continues, try using a different outlet. 3. Push/reset the circuit breaker. If the issue persists, contact your service provider.

Summary

Invacare Platinum 10 L Oxygen Concentrator User Manual

General Information

Symbols and Safety Signals

Explains warning symbols, signal words, and their meanings for safety.

Intended Use and Indications

Describes purpose, application, and medical conditions for concentrator use.

Product Description and Contraindications

Details technology and lists contraindications for the concentrator.

Safety Guidelines and Precautions

Label Locations and Radio Interference

Identifies label placements and addresses RF interference with wireless devices.

General Safety and Operation

Provides general safe operation instructions for the concentrator.

Components and Accessories

Component Identification

Labels and describes the main parts of the oxygen concentrator.

Pneumatic Diagram

Illustrates internal airflow and pneumatic connections.

Optional Accessories

Lists and describes compatible accessories.

Setup and Storage

Unpacking and Inspection

Instructions for unboxing and checking the concentrator for damage.

Storage Recommendations

Guidelines for storing the concentrator properly.

Usage and Operation

Introduction and Location Selection

Overview of usage and criteria for placing the concentrator.

Concentrator Setup and Power On

Guide for connecting, setting up humidifier, and powering on.

Flowrate and Unit Indicators

How to adjust flowrate and understand unit indicators without SensO2.

Maintenance Procedures

Service Life and Cabinet Cleaning

Information on product lifespan and cleaning the exterior.

Filter and Humidifier Maintenance

Steps for cleaning cabinet filters and the humidifier.

Inter-Patient Cleaning and Checklist

Protocols for disinfection between patients and a maintenance checklist.

After Use and Product Lifecycle

Recycling Information

Guidance on environmentally responsible disposal.

Wear and Tear Components

Lists components subject to wear and factors affecting them.

Troubleshooting Guide

Common Issues and Solutions

Addresses common symptoms, causes, and solutions for device problems.

Technical Specifications

Electrical, Sound, and Pressure Data

Details electrical requirements, sound levels, and pressure specifications.

Flow Range and Alerts

Specifies flow range, output concentration, and alert conditions.

Product Warranty

North American Limited Warranty

Outlines the terms, conditions, and exclusions of the product warranty.

Invacare PLATINUM 10L Specifications

General IconGeneral
TypeOxygen Concentrator
Oxygen Concentration93% ± 3%
Power SourceAC Power
Power Consumption350 W
Electrical Requirements50/60 Hz
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Sound Level45 dBA
Noise Level45 dBA