71
4
1
2
3
Solder off the pipe connected
with the compressor.
Removal Procedure
Disassemble the compressor
Solder off the welding spot of
capillary and valve and outlet
pipe of condenser.
Remove the 3 footing screws
of the compressor and
remove the
compressor.
Remove the 2 screws fixing
the gas valve. Solder off the
welding spot connecting gas valve
and air return pipe and remove
the gas valve.
(Note: it is necessary to warp
the gas valve when soldering
off the welding spot.)
Remove the 2 screws fixing
liquid valve. Solder off the
welding spot connecting liquid
valve and remove the liquid valve.
Remove the 3 footing
screw
s of the compressor
and rem
ove the
com
p
ressor.
.