Trouble Shooting 
 
82
OV1 
Over-voltage when 
acceleration 
OV2 
Over-voltage when 
deceleration 
OV3 
Over-voltage 
when constant 
speed running 
1. Dec time is too short and 
regenerative energy from the 
motor is too large. 
2. Input voltage is too high. 
1. Increase Dec time or 
connect braking resistor 
2. Decrease input 
voltage within 
specification. 
UV 
DC bus 
Under-voltage 
1. Open phase occurred with 
power supply. 
2. Momentary power loss 
occurred 
3. Wiring terminals for input 
power supply are loose. 
4. Voltage fluctuations in 
power supply are too large. 
Inspect the input power 
supply or wiring. 
OL1 Motor overload 
1. Motor drive heavy load at 
low speed for a long time. 
2. Improper V/F curve 
3. Improper motor’s overload 
protection threshold (PB.01)
4. Sudden change of load. 
1. Select variable 
frequency motor. 
2. Check and adjust V/F 
curve. 
3. Check and adjust 
PB.01 
4. Check the load. 
OL2 Inverter overload 
1. Load is too heavy or 
Acc/Dec time is too short. 
2. Improper V/F curve 
3. Capacity of inverter is too 
small. 
1. Increase Acc/Dec 
time or select bigger 
capacity inverter. 
2. Check and adjust V/F 
curve. 
3. Select bigger capacity 
inverter. 
SPI  Input phase failure 
1. Open-phase occurred in 
power supply. 
2. Momentary power loss 
occurred. 
3. Wiring terminals for input 
power supply are loose. 
4. Voltage fluctuations in 
power supply are too large. 
5. Voltage balance between 
phase is bad. 
Check the wiring, 
installation and power 
supply. 
SPO 
Output phase 
failure 
1. There is a broken wire in 
the output cable 
2. There is a broken wire in 
the motor winding. 
3. Output terminals are 
loose. 
Check the wiring and  
installation. 
EF External fault 
Sx: External fault input 
terminal take effect. 
Inspect external 
equipment.