EasyManua.ls Logo

INVT CHV180-7R5G-4

INVT CHV180-7R5G-4
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHV180 series frequency inverter special for elevator Appendix D
.150.
Function
Code
Name Description
Factory
Setting
Mod
ify
LCD Display
P9.07
Threshold of over
speed deviation
0.0%~50% 0.0~50
20.0
%
P9.08 Reserved 0.000~10.000s
0.000~10.0
00
0.50
00
RESERVE
PA Group: Serial communication
PA.00
Local address
1~247
0: broadcast address
1
LOCAL
ADDRESS
PA.01
Communication baud
rate selection
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
4
BAUD RATE
PA.02
Data format
0: No p
arity (8,N,2) for
RTU
1: Even parity (8,E,1)
for RTU
2: Odd parity (8,O,1)
for RTU
3: No parity (8,N,2) for
ASCII
4: Even parity (8,E,1)
for ASCII
5: Odd parity (8,O,1)
for ASCII
6: No parity (7,N,2) for
ASCII
7: Even parity (7,E,1)
for ASCII
8: Odd parity (7,O,1)
for ASCII
1
DATA
FORMAT
PA.03
Communication
response delay time
0~20ms 0
COM DELAY
TIME

Table of Contents