EasyManua.ls Logo

INVT CHV180-004G-4 - User Manual

INVT CHV180-004G-4
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CHV180 Series
Special Inverter for Elevators

Table of Contents

Questions and Answers

  • M
    Michelle ClarkeSep 17, 2025
    What does FAE mean on INVT CHV180-004G-4 Inverter?
    • B
      brownsandraSep 18, 2025
      If your INVT Inverter displays 'FAE', it indicates a fault of brake feedback. Check the elevator control system.
  • B
    brittanyyangAug 25, 2025
    What causes OC3 error on INVT CHV180-004G-4?
    • L
      Lori EricksonAug 25, 2025
      If your INVT Inverter displays 'OC3', it could be due to load transients, abnormal load (check the load and reduce the transients), low voltage (check the input power), insufficient inverter power (select a bigger capacity inverter), or issues with the encoding disk in a closed-loop system running at high speed (check the encoding disk and wiring).
  • B
    bethmullinsAug 25, 2025
    Why does my INVT CHV180-004G-4 Inverter show OV2 error?
    • M
      Michelle Cruz DVMAug 26, 2025
      If your INVT Inverter displays 'OV2', it could be due to a short deceleration time (increase the deceleration time), high load inertia (increase proper braking kits), or abnormal input voltage (check the input power).
  • M
    mmooreAug 26, 2025
    What does OC2 mean on my INVT CHV180-004G-4?
    • S
      Susan HoffmanAug 27, 2025
      If your INVT Inverter displays 'OC2', it could be due to a short deceleration time (increase the Dec time), high load inertia torque (add proper braking kits), or the inverter power being too low (select a bigger capacity inverter).
  • E
    Emma MillerSep 18, 2025
    What does TbE mean on INVT CHV180-004G-4?
    • M
      morganmichaelSep 18, 2025
      If your INVT Inverter displays 'TbE', it means the contactor feedback is fault. Check the elevator control system.
  • S
    Samuel SimmonsSep 23, 2025
    How to fix SPO error on INVT Inverter?
    • D
      Donald Smith Jr.Sep 23, 2025
      If U, V and W phase loss output, check the wiring, motor and cable.
  • C
    catherine83Sep 9, 2025
    What does EEP error mean on INVT CHV180-004G-4?
    • Q
      qparksSep 9, 2025
      If your INVT Inverter displays 'EEP', it could be due to a read/write fault of control parameters (press STOP/RST to reset) or EEPROM damage (ask for support).
  • D
    David ClarkeSep 10, 2025
    Why is my INVT CHV180-004G-4 showing OV3 error?
    • C
      Chloe ColeSep 10, 2025
      If your INVT Inverter displays 'OV3', it could be due to abnormal input voltage changes (install input reactor) or high load inertia (add proper braking kits).
  • C
    Collin WhiteSep 3, 2025
    What should I do if my INVT CHV180-004G-4 Inverter is running but the motor won’t move?
    • T
      Tracy RobinsonSep 3, 2025
      If your INVT Inverter displays 'Motor doesn’t move after inverter running', inspect if there is balanced three-phase output among U, V, and W. If yes, then motor could be damaged, or mechanically locked. Please solve it. If the output is unbalanced or lost, the inverter drive board or the output module may be damaged. ask for support.
  • H
    Heather SloanSep 1, 2025
    How to troubleshoot no display on INVT CHV180-004G-4 Inverter after power on?
    • M
      Mike WoodSep 1, 2025
      If your INVT Inverter displays 'No display after power on', inspect whether the voltage of power supply is the same as the inverter rated voltage or not with multi-meter. If the power supply has problem, inspect and solve it. Also inspect whether the three-phase rectify bridge is in good condition or not. If the rectification bridge is burst out, ask for support. Check the CHARGE light. If the light is off, the fault is mainly in the rectify bridge or the buffer resistor. If the light is on, the fault may be lies in the switching power supply. Please ask for support.

Summary

Safety precautions

3. Disassembly and installation

4. Wiring

Terminal configuration

Details the layout and function of main circuit and control terminals.

Typical wiring diagram

Provides a comprehensive wiring diagram for system setup.

Wiring the main circuits

Covers connections for power supply, motor, and braking units.

Installation guidline to EMC compliance

Provides guidelines for proper installation to ensure electromagnetic compatibility.

5. Operation

Operating keypad description

Explains the functions of the inverter's keypad buttons and indicators.

Operation process

Details procedures for parameter setting, fault reset, and autotuning.

6. Detailed function description

P0 Group-Basic function

Configures fundamental inverter settings like speed control mode and run command source.

P1 Group-Speed curve

Adjusts acceleration, deceleration, and multi-step speed settings for smooth operation.

P2 Group-Motor parameters

Sets motor-specific parameters for optimal performance and autotuning.

P3 Group-Vector control

Optimizes vector control performance with PI loop and filter settings.

P9 Group - Protection parameters

Configures various protection features like phase-failure and overload protection.

8. Trouble shooting

Fault and trouble shooting

Provides a table of fault codes, types, reasons, and solutions for diagnosing issues.

Common faults and solutions

Discusses common operational faults like no display, motor not moving, and tripping.

9. Maintenance

10. Communication protocol

Appendix A: Commissioning guide

Runing and parameter-adjusting

Guides on setting parameters, debugging, autotuning, and S-curve adjustment.

Appendix D Function parameters

P0 Group: Basic function

Configures fundamental inverter settings like speed control mode.

P1 Group: Speed curve

Adjusts acceleration, deceleration, and multi-step speed settings.

P2 Group: Motor parameters

Sets motor-specific parameters for optimal performance and autotuning.

P3 Group: Vector control

Optimizes vector control performance with PI loop and filter settings.

P9 Group: Protection function

Configures various protection features like phase-failure and overload protection.

INVT CHV180-004G-4 Specifications

General IconGeneral
BrandINVT
ModelCHV180-004G-4
CategoryInverter
LanguageEnglish